IP55 Wssx Automatic Control Alarming Electric Contact Bimetal Thermometer Temperature Sensor Gauge Instrument

Product Details
Customization: Available
Standard: Celsius/Fahrenheit
Accuracy: 1.0/1.5
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (32)
Find Similar Products

Basic Info.

Model NO.
WSSX
Usage
Industrial, Household
Display
Pointer
Material
Bimetallic
Hygrometer Type
Electric
Diameter of Dial
100
Response Time
≤40s
Protection Class
IP55
Temperature Measuring Range
-80ºC~500ºC
Measuring Object
Liquid/Vapors/Gas
Transport Package
Wooden Box
Specification
As your requirements
Trademark
Huining
Origin
China
HS Code
90251990
Production Capacity
5000 PCS/Month

Product Description

100mm Axial/Radial/Universal Location  Movable outer/ Inner/ Fixed/Compression Thread/Flange Mounting  Protection/Anticorrosive Electric Contact Bimetallic Thermometer
Application:
The electric contact bimetal thermometer is applied to the production site to automatically control and alarm the temperature. The thermometer can directly measure the temperature of liquids, vapors and gaseous media ranging from -80ºC to 500ºC in production processes.
Feature:
1. Display temperature on site, intuitive and convenient.
2. Safe and reliable, long service life.
3. A variety of structural forms to meet different requirements.
4. Automatically break power and alarm.
Working Principle:
The electric contact bimetal thermometer uses the temperature change to drive the contact change. At the same time, it contacts or disconnects the upper and lower limit contacts, so that the relay in the circuit works, thus automatically controlling and alarming. 
Error:
1. setting point error should be no more than 1.5times of  basic error limit.
2. switching error should be no more than 1.5times of basic error limit.
3. repeat range of thermometer should be no mre than 1/2 the absolute value of basic error.
Operating temperature:
Temperature Relative Humidity
-25ºC~+55ºC ≤85%

Electric Parameters
Rated Power VA MAX. Working Voltage Max. Allowed Current 
10 220 A.C 0.7A
24 D.C

Insulation Resistance
Rated Voltage Testing Voltage D.C Insulation Resistance
24 D.C 100 7
220 A.C 500 20

 